Location: Home>Products Introduction>Press

HM26 Ceramic Capacitor Pressure Transducer

Description

HM26 ceramic capacitor pressure transducer adopts internationally advanced ceramic capacitor sensor, supported with high–accuracy electronic elements, and assembling with strict process. It adopts dry pressure measuring technology without intermediate liquid, thick membrane electronic technology, SMT (surface mount technology) and PFM signal transferring technology to fully play a role of technical advantages for ceramic capacitor sensor so as to make that the pressure transducer features excellent technical performance. It features strong anti–overloading and anti–impact capacity, high stability, and very high accuracy of measurement. This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.

Features of Product

☆ Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale 

☆ Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability 

☆Small temperature drifting due to without intermediate liquid for measuring element 

☆ Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure 

☆ Pure ceramic substrate will not result process pollution. It applies to food and medical industrial. 

☆ Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof. 

☆ Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5

Application of Product

Details


     Measuring range

-100KPa ~ 0 ~ 5KPA…100MPa

Overloading capacity

3 ~ 100 times of    maximum rated pressure (the smaller scale, the bigger over pressure times

Type of pressure

Gauge pressure,  absolute pressure

Medium to be measured

Corrosive liquid, gas,    and vapor (the medium compatible with AL2O3  and 1Cr18Ni9N)

Overall accuracy
     Non - linear, repeatability,    lagging

 ± 0.1% FS

 ± 0.25% FS

 ± 0.4% FS

Medium temperature

-40~+125℃

 

Ambient temperature

-40~+85℃

 

Compensating    temperature

-20~+80℃

 

Long – term stability

 ± 0.1% FS / year

Zero point temperature    drifting

 ± 0.02% FS / ℃

Sensitivity    temperature drifting

 ± 0.02% FS / ℃

Range of power    supplying

12 ~ 36V DC (    generally 24V DC)

Signal output

4~20mA / 1-5V DC / 0~5V DC

Load resistance

≤(U - 12) / 0.02Ω

Material of structure

Membrane: AL2O3  ceramic

Enclosure: Cast    aluminum with low copper  content

Connecting material:    1Cr18Ni9N

Sealing structure: NBR,    PTFE or Fluorubber

Safe explosion – proof

Ex ia II CT5

Enclosure protection    degree

Plug type (IP65);    cable type (IP67)

Response time (10% ~ 90%)

≤1ms

Weight

Approx. 500g

Thermal lagging

 ± 0.01% FS (typical)

Tolerance of vibration

≤ ± 0.01% FS(Axles X, Y,    and Z, 200Hz / g)

Product selection

HM26

Ceramic Capacitor Pressure Transducer

 

Guideline of Selection

Ceramic    Capacitor Pressure Transducer

 

Type of pressure

Gauge pressure (G, may not be indicated); absolute pressure (A), combined    pressure with positive and negative pressure (F)

 

 

Range

Measuring Range

 

 

0 ~ X KPa or 0 ~ X MPa

 

 

 

 

 

Code

Overall accuracy (linear + repeatability + lagging)

 

 

 

 

 

1

 ± 0.4% FS

 

 

 

 

 

2

 ± 0.25% FS

 

 

 

 

 

3

 ± 0.1% FS

 

 

 

 

 

 

 

Code

Signal Output (Standard power supply of energization

 

 

 

 

 

 

 

A1

4 ~ 20mA (12 ~ 36V DC)

 

 

 

 

 

 

 

V1

1 ~ 5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

V2

0 ~ 5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

V3

0.5 ~ 4.5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

 

 

Code 

Additional functions

 

 

 

 

 

 

 

 

 

F1

M20 x 1.5 external thread

 

 

 

 

 

 

 

 

 

F2

G 1 / 4 external thread

 

 

 

 

 

 

 

 

 

F0

Special

 

 

 

 

 

 

 

 

 

B1

Stainless steel structure

 

 

 

 

 

 

 

 

 

B2

PMP 133 aluminum alloy structure ( E + H)

 

 

 

 

 

 

 

 

 

P

Flushed membrane type

 

 

 

 

 

 

 

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

 

 

 

 

HM26 G( 0 ~    10KPa)  

 

— 1

— A1

— F1

— B1  -E Ceramic Capacitor    Pressure Transducer


Tips of Selection

  1. The medium to be measured shall be compatible with the material contacting with the product.
  2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
  3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


bottom-nav_01.png

主要产品:
HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital • Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |