HM10 High - accuracy Pressure Sensor

Description

HM10 High - accuracy piezoresistive pressure sensor is encapsulated in stainless steel case through assembly and commissioning adopting advanced silicon piezoresistive sensitive elements made by German HELM Company. Both the case and the port are made of stainless steel. The medium are of good compatibility, with stable and reliable performance, and high accuracy. The gasket is applied on the end face.

Features of Product

☆ Measuring range: -0.1MPa ~ 0 ~ 10KPa … 70MPa 

☆ Fully made of stainless steel 

☆ Standard thread pressure-leading measuring method 

☆ Constant - current and - voltage source power supplying 

☆ Laser resistance adjusting compensation and full scale temperature performance 

☆ Using solid-state piezoresistive pressure sensor, with high reliability and high accuracy. 

☆ Designed with small dimensions, and many optional structural forms

Application of Product

☆  Measurement of pressure for all kinds of dynamic and static gas and liquid medium 

☆  Automobile electronic device 

☆  Airspace and aerospace 

☆  Pneumatic pressure control 

☆  Ventilation system 

☆  Industrial measurement

Details

Technical Data 

Measuring Range

-0.1MPa ~ 0 ~ 10KPa … 70MPa

Over pressure

Two times of measuring scale for over pressure

Power supplying

1.5mA DC constant current

 10 ~ 24V DC constant voltage

Zero point output

0 ± 2 mV DC

0 ± 2 mV DC

Full-range output

70 ~ 110mV DC

70 ~ 110mV DC

Overall accuracy
           Linear, repeatability, lagging

 ± 0.1% FS

 ± 0.25% FS

 ± 0.4% FS

Long-term stability

 ± 0.1% FS / year

Range of operating temperature

-40 ~ +85 ℃

Range of compensating  temperature

-40 ~ +50 ℃

Temperature performance

Zero point temperature coefficient: ± 0.02% FS (Typical)  
            ±0.04% FS (Max.)  

Sensitivity temperature coefficient: ± 0.02% FS (Typical) 
            ± 0.04% FS (Max.)

Thermal lagging

 ± 0.1% FS

 

 

 

 

Material

Enclosure: S / S 1Cr18Ni9Ti

Membrane: S / S 316L

Cable: PVC

Sealing: Fluorubber Sealing Ring

Electrical connection

PG7 Cable Wiring

Tie-in DIN 43650

Response time (10% ~ 90%)

≤ 1 ms

Insulating resistance

100MΩ / 500V DC

Enclosure protection degree

IP 67 (Cable Type)

IP 65 (Socket Type)

Weight

Approximately 250g

Vibration

No change under 10gRMS, 20 ~ 2000Hz

Impact

100g, 11ms

Service life

1 x 108 Pressurized Cycle

Medium compatibility

The gas or liquid compatible with 316 stainless steel

Product selection

High - accuracy Pressure Sensor 

 

Guideline of Selection

High - accuracy Pressure Sensor

Pressure type

Gauge pressure (G, may not be indicated); Absolute pressure (A)

 

Range

(0 ~  X kPa or 0 ~ X MPa)

 

 

 

Code

Overall accuracy (linear + repeatability + lagging)

 

 

 

1

 

 ± 0.4% FS

 

 

 

2

 

 ± 0.25% FS

 

 

 

3

 

 ± 0.1% FS

 

 

 

 

 

 

Code

Power Supply of energization

 

 

 

 

 

 

D1

10 ~ 24V DC constant voltage

 

 

 

 

 

 

D2

1.5mA DC constant current

 

 

 

 

 

 

 

 

Code

Signal Output

 

 

 

 

 

 

 

 

V1

0 ± 2mV ~ 90 ± 20mV

 

 

 

 

 

 

 

 

 

 

Code 

Additional functions

 

 

 

 

 

 

 

 

 

 

F1

M20 x 1.5 external thread

 

 

 

 

 

 

 

 

 

 

F2

G 1 / 4 external thread

 

 

 

 

 

 

 

 

 

 

F3

1 / 4 NPT external thread

 

 

 

 

 

 

 

 

 

 

F4

1 / 2 - 20 UNF - 2A

 

 

 

 

 

 

 

 

 

 

F0

Special

 

 

 

 

 

 

 

 

 

 

W1

Cable type (IP67 , 2M)

 

 

 

 

 

 

 

 

 

 

W3

Airspace and aerospace Socket type (IP65)

 

 

 

 

 

 

 

 

 

 

P

Flushed membrane type

 

 

 

 

 

 

 

 

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HM10 ( 0 ~ 200 kPa)   — 1    —    D1   —V1  —    F2   — W1  —E High - accuracy Pressure Sensor

 

 

 

Tips of Selection 

 Correctly adopt sealing means to prevent the product stability from influencing by the installing stress when installation of the flushed membrane on the site. We may provide the produCT5 withstanding a pressure of 70MPa or higher or produCT5 with wide temperature compensation range at the user’s requests. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier. Please contact us in case of the other special requirements and clearly indicate them when placing an order.  

bottom-nav_01.png

主要产品:
HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital • Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |